Pallet Racking Specifications Singapore: Beams & Loads
Pallet Racking Specifications Singapore: Beams & Loads
July 5, 2026
Pallet Flow Racking Cold Chain & Pharma Singapore
Pallet Flow Racking Cold Chain & Pharma Singapore
July 12, 2026

Pallet Racking Specifications Singapore: Frames, Uprights

Pallet racking specifications in Singapore start with the upright frame, the part that carries every beam level down to the slab. This blog will walk you through the specification lines for frames: post profile, frame depth and height, bracing, baseplates and anchors, and the SS EN 15512 design basis behind every rated figure.

What does a pallet racking frame specification cover?

A pallet racking specification splits into two halves. The beams set what each level carries, and the upright frames set what the whole bay carries down to the floor. Beam profiles and ratings are covered in our guide to pallet racking beam sizes and ratings, so this page covers the frame half.

An upright frame is two vertical posts joined by horizontal and diagonal braces, standing on two baseplates that are anchored to the slab. Every component in that list has its own specification line, and the frame is only as strong as the weakest of them.

How is a pallet racking beam's load rating decided?

NTL’s upright frame specifications at a glance

The table sets out the frame specification ranges NTL publishes for standard and heavy duty pallet racking. The rated figure for your bay comes from the design calculation at your height and beam level spacing, so treat these as ranges to check a quotation against.

Specification Standard pallet racking Heavy duty pallet racking
Upright post profile depth 70 to 90 mm 100 to 120 mm (up to 140 mm on very tall frames)
Post steel thickness 1.8 to 2.0 mm 2.0 to 2.5 mm or thicker
Example frame capacity About 8 tonnes per frame for a 90 mm post About 12 tonnes per frame for a 100 mm post
Frame depth 900 mm or 1,100 mm (600, 800 and 1,200 mm less common) Set by the load; 1,200 mm in some heavy duty layouts
Frame height 2,400 to 12,000 mm; frames above 8 m are spliced Same range, set by the design
Baseplate thickness 4 to 6 mm 8 to 12 mm
Anchors M12 expansion anchors M16 or M20, often chemical anchors

Every figure in a quotation should trace back to a design calculation. The same frame components run through NTL Storage’s pallet racking systems, from selective and narrow aisle racking to double deep.

How are upright post profiles specified?

Profile depth and steel thickness

The post is a cold rolled steel section, punched with slots along its face for the beam connectors. Its depth and steel thickness set how much axial load it carries before it buckles. A deeper profile resists buckling better, and thicker steel adds strength to the whole section.

The two are easy to confuse on site. A 90 mm post rated about 8 tonnes per frame and a 100 mm post rated about 12 tonnes look much alike from the aisle, yet loading the lighter frame to the heavier one’s figure overloads it by half. When to step up to heavy duty sections is set out in our comparison of heavy duty vs standard pallet racking.

Why the frame rating changes with the layout

A frame rating belongs to one configuration. The length of post between beam levels decides how easily it buckles, so the same frame with widely spaced levels carries less than it does with closely spaced ones. Raising the first beam level to clear a pallet truck has the same effect.

This is why a frame rating on a quotation without a stated height and beam level spacing tells you very little. Ask for the rated capacity at your exact layout, and ask again whenever the beam levels are moved.

How are upright frames sized for gauge and load?

What frame depth and height do you need?

Frame depth follows the pallet

Frame depth is the distance from the front post to the back post. NTL sizes it so the pallet overhangs the frame by roughly 50 mm at the front and back, which makes the frame about 100 mm shallower than the pallet’s depth into the rack.

For the common 1,000 × 1,200 mm pallet, the depth depends on which way it goes in: a 1,100 mm frame with the 1,200 mm side running into the rack, or a 900 mm frame with the 1,000 mm side running in. Check the pallet orientation with the forklift operator before the frames are ordered, because frame depth cannot be changed later.

Frame height and splices

NTL’s frames run from 2,400 mm to 12,000 mm, with 6 m the usual height for reach truck work in JTC estates. Height is set by the clear height under the lowest obstruction, the forklift’s lift height and the sprinkler clearance above the top pallet.

Taller frames are made from two lengths joined with a splice. On frames above 8 m, the splice has to develop the full capacity of the upright and is positioned away from a loaded beam level.

How is a pallet racking frame braced?

Frame bracing

The horizontal and diagonal braces between the two posts turn them into a stiff lattice. That lattice keeps the frame stable across the aisle and stops each post buckling between brace points. A bent or missing brace weakens the whole frame, even when both posts look straight.

Down aisle stability and back to back runs

Along the aisle, most selective racking relies on the stiffness of the beam to upright connections to resist sway. Taller or heavier runs may add spine bracing at the back of the frames. SS EN 15512 covers both unbraced and braced systems, and the design states which one you have.

Back to back runs are tied together with row spacers, which hold the two lines of frames at a fixed gap and let them steady each other. Spacers are a frequent omission on cheaper quotations, because they add steel without adding pallet positions.

What baseplate and anchor specifications go with the frame?

Floor fixing

Every frame stands on two baseplates, and each baseplate passes its post’s load into the slab. SEMA’s design code, as SEMA set out in Warehouse & Logistics News, requires all uprights in racking used with mechanical handling equipment to be floor fixed. Each upright to floor connection should transfer at least 3 kN in tension and 5 kN in shear.

That is a minimum. The rack designer sets the anchor type, diameter and embedment depth for the actual loads, and checks it against the slab. 

Plumb and the floor

Frames have to stand plumb to carry their rated load. EN 15620 allows a frame to lean by no more than its height divided by 350 in standard racking, which is 17 mm on a 6,000 mm frame. Very narrow aisle racking is held to height divided by 500.

Uneven slabs are levelled with steel shims under the baseplate, kept within the rack maker’s limit and matched to the plate’s footprint. A floor that needs a tall shim stack has a flatness problem that shims will not fix.

Which standards govern pallet racking specifications in Singapore?

Four European standards, adopted in Singapore, cover a pallet rack from purchase to daily use:

Standard What it covers
SS EN 15629 What the user and supplier must specify to each other: goods, pallets, handling equipment, floor, baseplate and anchorage information
SS EN 15512 The structural design rules for adjustable pallet racking, braced and unbraced
SS EN 15620 Tolerances, deformations and clearances, including plumb limits
SS EN 15635 Use and maintenance once the rack is loaded, including inspection

The design standard has a scope worth checking on any quotation. EN 15512 states that it does not apply to mobile storage, drive in, drive through or cantilever racks, or to static steel shelving. It also sets no specific rules for seismic assessment, which comes from separate codes where the building designer requires it.

EN 15629 is the one buyers skip. It lists the project information the designer needs from you, such as the floor specification, baseplate and anchorage details and the goods to be stored. Giving that information up front is what makes the frame ratings in a quotation meaningful.

What should a frame specification on a quotation show?

A complete quotation states, for the frames:

  • post profile and steel thickness;
  • frame depth and height, with splice positions on tall frames;
  • rated frame capacity at your beam level spacing;
  • bracing, spine bracing and row spacers in the bill of materials;
  • baseplate size, anchor type and embedment, and who supplies the anchors;
  • the design standard, normally SS EN 15512.

Specifying pallet racking frames with NTL Storage

NTL Storage has supplied and installed pallet racking in Singapore since 2012. Send us your pallet size and orientation, heaviest pallet weight, clear height and forklift model, and we will specify the frames, bracing and anchors for your layout.

FAQs About Pallet Racking Specifications

What size are pallet racking uprights in Singapore?

NTL’s standard posts are 70 to 90 mm deep in 1.8 to 2.0 mm steel, and heavy duty posts 100 to 120 mm deep in 2.0 to 2.5 mm steel. As a guide, a 90 mm post is rated about 8 tonnes per frame and a 100 mm post about 12 tonnes, at a stated height and beam spacing.

What frame depth do I need for a 1,000 × 1,200 mm pallet?

It depends on orientation: a 1,100 mm frame with the 1,200 mm side running into the rack, or a 900 mm frame with the 1,000 mm side running in. Either way the pallet overhangs the frame by about 50 mm at the front and back.

How tall can pallet racking frames be?

NTL supplies frames from 2,400 mm to 12,000 mm. Frames above 8 m are spliced, and the splice must carry the full upright capacity. The usable height is set by clear height, forklift lift height and sprinkler clearance, and a taller frame carries less per frame unless its post is heavier.

Does pallet racking have to be bolted to the floor?

Yes. SEMA’s design code requires every upright in racking used with forklifts to be floor fixed, with each fixing resisting at least 3 kN in tension and 5 kN in shear. The rack designer specifies the actual anchor from the loads and the slab.

Which standard is pallet racking designed to in Singapore?

SS EN 15512, the structural design standard for adjustable pallet racking. It does not cover drive in, drive through, mobile or cantilever racks, or steel shelving. SS EN 15620 sets tolerances, SS EN 15629 sets what to specify and SS EN 15635 covers use and inspection.

What is the plumb tolerance for pallet racking frames?

Under EN 15620, a standard pallet racking frame may lean by no more than its height divided by 350, which is 17 mm on a 6,000 mm frame. Very narrow aisle racking is held tighter, at height divided by 500.