High Density Racking Singapore: 4 Systems Compared
August 20, 2025
Essential Seismic Considerations For Racking Design
August 22, 2025

Choosing The Right Warehouse Racking System Guide

Choosing The Right Warehouse Racking System

Racking for a leased warehouse in Singapore has to work for the whole lease, from consent on day one to reinstatement on the last day. This blog will walk you through lease length, JTC and landlord consent, anchor holes and reinstatement, moving racking at lease end and freestanding versus fixed mezzanines.

Why does a lease change the racking decision?

Racking usually outlasts the lease it was bought for. SEMA, the UK storage equipment association, notes that well designed and maintained racking can last the life of a business, and our guide to how long pallet racking lasts explains what shortens that life. Most racking is retired because the layout no longer fits, not because the steel has worn out.

A lease puts a deadline on the layout. When it ends, you either renew and keep the racking, move it to a new unit or take it out and hand the floor back as you found it. Each outcome costs money, and the cheapest one depends on choices made at installation: what kind of system you buy, how it is fixed down and what you agree with the landlord.

man working with heavy wooden materials

How do you match the racking system to the lease length?

Start with how long you expect to stay, including any renewal option, then choose a system you can afford to remove or move at that point. The type of racking still follows your stock. Our guide on how to choose pallet racking covers that decision.

Lease position Better fit Think twice about
Short lease or uncertain renewal Selective racking, longspan or boltless shelving from standard components; freestanding modular mezzanine if extra floor area is essential Layouts that need floor works, guided aisles or a mezzanine tied into the building
Long lease or strong renewal option Any system the stock justifies, including denser layouts; planned reconfiguration as stock changes Assuming the next unit will take the same layout without changes
Planning to relocate later Standard bay widths and frame sizes that suit common units; a full parts list kept from installation Custom sizes cut to one building’s columns and clear height

Very narrow aisle racking is the clearest example of a system tied to its building. The guided trucks need rail or wire guidance and a floor flat enough for tall trucks to run safely, and that floor work stays behind when you leave.

What consent do you need from JTC and the landlord?

JTC premises

JTC’s Space Submission Handbook exempts shelves and racks from submission only within four limits:

  • the rack is no more than 3.0 m high;
  • it is no more than 1.2 m wide;
  • its gross weight, including stored goods, stays within 7.5 kN/m² or the design imposed load, whichever is lower;
  • a clear passageway of at least 1.2 m is kept.

The exemption also expects stored material to be non combustible and racks not to be fixed to non load bearing partition walls. Racks used as an access platform are not exempt.

Most pallet racking goes past those limits, so it needs a submission. Works that affect building loading need a Professional Engineer’s endorsement, and any change in gross floor area needs a Qualified Person’s endorsement.

Private landlords

Leases from private landlords usually require written consent for fit out works, and the lease sets the reinstatement terms. Send the landlord the layout, rack heights, bay loads and anchor details before ordering. Ask for the slab rating at the same time, since it caps the bay loads you can use.

What happens to anchor holes and the floor when the lease ends?

JTC’s handbook states that tenants are still required to reinstate premises to the original handover condition when the tenancy expires or ends, unless the building owner agrees otherwise in writing. Racking anchors leave holes in the slab, and every hole is part of that reinstatement.

Plan for it at installation, not at handover:

  • photograph the floor before any racking goes in;
  • keep the anchor layout drawing from the installer;
  • confirm the slab type before drilling, since JTC’s exemption conditions for fixings in other fit out works exclude prestressed slabs, hollow core slabs and mass engineered timber;
  • agree in writing how anchor holes will be filled and finished at the end.

JTC does not allow hacking or coring of structural columns, beams and slabs during fit out works. Racking anchors should be specified by the installer for the slab you actually have. On a hollow core or prestressed slab, the fixing method needs an engineer’s input before any drilling.

Should you reconfigure or move racking when the lease ends?

Renewing the lease

If you stay, the racking can be adapted to the stock you hold by then. Moving beam levels or changing bay layouts needs the supplier to check the new arrangement, and new load notices before use. 

Moving to a new unit

Racking can move with you, but it is not a straight transfer. Every component is inspected as it comes down, and damaged parts are replaced with the original supplier’s matching components. The layout is then rated again for the new floor, clear height and beam levels.

The new unit needs its own consent submission and new load notices. Parts from another maker should never be mixed in to make up numbers. If you are weighing a move against staying, our comparison of re-rack vs mezzanine vs move sets the options side by side.

Handing back the unit

Leave enough time before the lease ends to dismantle the racking, fill the anchor holes and make good the floor finish. Racking that is taken down carefully and labelled by component can be stored or sold. Racking pulled down in a rush usually cannot. 

Freestanding or fixed mezzanine: which suits a leased unit?

Freestanding mezzanine

A freestanding mezzanine stands on its own steel columns, bolted to the slab, with no connection to the building’s structure. A modular block mezzanine is built from interchangeable steel modules, so it can be extended, reduced or taken down and rebuilt elsewhere. That makes it the usual choice when the lease is short or renewal is uncertain.

Fixed mezzanine

A fixed mezzanine is tied into the building, for example connected to its columns or built with concrete. It can feel more permanent, but removing it at the end of the lease is demolition and reinstatement work, often needing an engineer to confirm the building is left as it was.

Approvals apply to both

Both types need approval before construction. JTC requires PE (Civil) endorsed drawings and calculations for a mezzanine floor or storage platform, with BCA and SCDF compliance.

The SCDF Fire Code 2023 sets conditions for mezzanines in warehouse units in clause 9.8.1a.(2). These include an aggregate area of no more than 60 m² per unit and a structure of at least one hour fire resistance.

A mezzanine can also add gross floor area, and JTC requires a Qualified Person’s endorsement for any change in GFA. 

Planning racking for your lease with NTL Storage

NTL Storage has supplied and installed racking in Singapore since 2012. Tell us how long your lease runs, whether the unit is JTC or private, the slab rating and what you store. We will propose a layout that you can get approved, use for the whole lease and take down cleanly at the end.

FAQs About Racking For Leased Warehouses

Do I need JTC approval to install racking?

Usually. JTC exempts racks only up to 3.0 m high and 1.2 m wide, with gross weight within 7.5 kN/m² or the design imposed load and a 1.2 m clear passageway. Racks used as an access platform always need consent. Most pallet racking exceeds these limits and needs a submission.

Do I have to fill the anchor holes when my lease ends?

Usually yes. JTC requires tenants to reinstate premises to the original handover condition when the tenancy ends, unless the owner agrees otherwise in writing, and most private leases have a similar clause. Keep the anchor layout and agree the reinstatement method at installation.

Can I take my racking with me when I move?

Yes, if it is inspected and rated again. Every component is checked as it comes down, damaged parts are replaced with the original maker’s parts, and the layout is rated for the new floor and beam levels. The new unit needs its own consent and new load notices.

Is a mezzanine a good idea in a leased warehouse?

It can be, if it is freestanding. A modular mezzanine bolted to the slab can be dismantled and reused when the lease ends. A mezzanine tied into the building becomes reinstatement work. Either type needs PE endorsed drawings and BCA and SCDF compliance before construction.

What racking suits a short lease?

Standard selective racking, longspan or boltless shelving built from standard components, fixed only with anchors into a sound slab. These come down cleanly and suit other units. Avoid layouts that need floor works, guided aisles or a structure tied into the building.

Who is responsible for racking safety in a leased warehouse?

The occupier. MOM’s circular on the safe use of storage racks expects occupiers and employers to take all reasonably practicable measures to keep storage racks safe, including regular inspection and repair. The landlord’s consent covers the installation, not how the racking is used day to day.

Comments are closed.